Technical guide · Drag chain cables · Troubleshooting

A failed drag chain cable is evidence. Each failure mode — corkscrewing, broken cores, worn-through jackets, phantom signal faults — has a recognisable signature and a short list of causes, and in our experience the large majority trace back to installation or specification, not to the cable’s manufacturing. Learn to read the cable before you order the next one.

1. Corkscrewing (the cable spirals inside the chain)

Signature: the cable takes a permanent helical set, climbs the chain’s side walls, and wears on one side. It appears weeks or months after installation, never on day one.

Cause: stored twist. The cable was uncoiled in loops or pulled off the side of a stationary reel, winding a full turn of twist into every metre. In service the cores try to return to their manufactured lay, and the cable screws itself into a spiral. A second cause is a chain filled with cables of wildly different diameters laid without separators, which wind around each other.

Fix: the twist cannot be adjusted out — replace the cable, unreel the new one tangentially from a rotating reel, and lay it out straight before fitting. See the installation rules.

2. Broken conductors (cores fail open-circuit)

Signature: one or more cores go open-circuit; the break is almost always at the bend apex or just behind a clamp. The jacket often looks perfect.

Causes, in order of frequency:

  • Chain radius below the cable’s dynamic minimum — strand fatigue concentrates at the tightest point of the bend (check with the bend radius table).
  • Cable installed under tension, so cores are dragged through the bend under load.
  • A clamp crushing the jacket, creating a hard point where bending starts.
  • An ordinary flexible cable (not chain-rated) used in a chain — its long lay length crushes cores against each other.

Fix: correct the radius, slack and clamping first; then replace with a chain-rated construction of the right speed class.

3. Jacket worn through or cracked

Signature: abrasion flats on one face, or cracks along the jacket — sometimes down to the shield or cores.

Causes: cables rubbing each other or the chain (no separators, overfilled chain); a heavy cable riding on a light one; or chemical attack — PVC jackets swell and crack under continuous cutting-oil and coolant exposure, which is a material mismatch, not a defect: the fix is PUR.

4. Intermittent signal faults (encoder errors, drive trips)

Signature: position faults and communication errors that come and go with axis position or speed — the cable “tests fine” on the bench.

Causes: an unshielded or overall-shielded-only cable carrying pair signals (encoder feedback needs twisted pairs with an overall shield — TRVVSP class); shields terminated in long pigtails instead of 360° clamps; power and feedback cables bundled in one compartment. Our shielding-grade guide covers the selection side.

Quick diagnosis table

What you seeMost likely causeFirst check
Cable spirals, wears one sideTwist stored at installationHow was it unreeled? Any separators?
Core open-circuit at the bendRadius below dynamic minimumChain R ÷ largest cable OD ≥ 7.5?
Core open-circuit behind clampCrushed clamp / hard pointClamp size and torque; free section after clamp
Jacket polished flat, then holedAbrasion — cables rubbingFill level, separators, mixed diameters
Jacket swollen, cracked near coolantPVC vs oil mismatchChange material to PUR
Encoder faults at certain positionsWrong shielding grade or pigtail shieldPair construction? 360° termination?
Everything fails early, all cablesUnderrated speed class for the dutyActual speed/travel vs cable class

When it really is the cable

Sometimes the cable is simply used up or wrongly bought. Rated life is finite — a medium-speed class cable that has genuinely run its millions of cycles has done its job. Two buying traps also show up repeatedly: a low-speed construction specified for a high-speed axis (the speed classes exist because lay length and materials differ), and undersized conductors — cables whose actual copper cross-section is below the marked size run hot and age fast. Both are visible before purchase if the construction data is on the table, which is why our selector publishes full construction, diameter and weight data for every type.

Frequently asked questions

Can a corkscrewed cable be straightened and reused?
No. The deformation is in the core assembly, not just the jacket. It will spiral again within weeks. Replace it and correct the unreeling method.
The new cable failed the same way as the old one. Bad batch?
Almost never. Identical repeat failure is the signature of an installation or specification cause — radius, tension, clamping or environment. Diagnose from the table above before ordering a third cable.
How do I tell abrasion wear from a manufacturing defect?
Abrasion is localised — one face, at contact points, often with matching witness marks on the neighbouring cable or chain. Defects are not position-dependent. Photograph the cable in place before removing it; the pattern is the diagnosis.
Is it worth repairing a damaged drag chain cable?
Joints inside a moving chain create hard points and fail quickly. Replace the full run; if the run is long, treat the removed cable as evidence and fix the cause first.

Send us a photo of the failed cable

Photograph the damage in place, tell us the machine, the chain size and how long the cable lasted. We will tell you which failure mode it is, what to change, and quote the replacement construction — before you spend money repeating the failure.

Request a diagnosis / quote EKM61100 — medium speed