Technical guide · Instrumentation cables · DJYPVP

DJYPVP is the double-shielded instrumentation cable: every twisted pair gets its own screen, and the whole bundle gets a second, overall screen. It is the cable for RS-485 buses, 4–20 mA loops and any analogue signal that has to survive next to drives, contactors and long parallel runs. Our cable selector lists 834 standard computer-cable constructions in this family — DJYPVP and its five siblings. This guide explains the whole family: how to read a model code, what each member is, and which one fits your signal.

DJYPVP instrumentation cable

1. What DJYPVP is

The build is a twisted-pair cable for instrumentation and computer duty: multi-strand ultra-fine bare copper conductors, polyolefin insulation (foamed PE on the catalogue RS-485 build), each pair individually screened, then an overall screen of aluminium foil plus tinned copper braid at 80% coverage or more, under a black or grey PVC sheath. Rated voltage is 300/500 V. The base product is our RS-485 & Instrumentation Cable, and the selector below it lists the full computer-cable grid — 834 standard constructions across six models, 1–16 pairs × 0.75–1.5 mm².

The two screens do different jobs. The pair screen stops one pair talking to its neighbour — crosstalk between a 4–20 mA loop and a fast digital pair in the same cable. The overall screen stops the outside world getting in: drive noise, mains hum and switching transients. A cable with only an overall screen, such as DJYVP, blocks the outside world but leaves the pairs to interfere with each other. That is the whole reason DJYPVP exists — and why it costs more than its single-screened sister.

834 standard constructions: DJYVP 96 + DJYPVP 90 + DJYVRP 192 + DJYPVRP 180 + DJYPVP22 96 + DJYPVRP22 180. Every one of them is listed in our cable selector with its stock code, construction, outer diameter and weight — the numbers in this guide are recomputed from that selector, not from a catalogue summary.

2. How to read a DJYPVP model code

The model names are construction codes. Each letter adds one fact about the build:

Code partMeaningWhat it tells you
DJYComputer / instrumentation cable baseTwisted-pair cable for signals and measurement, PE insulation
PPair screenEach twisted pair individually screened (DJYPVP, DJYPVRP)
VPVC sheathBlack or grey PVC outer sheath
POverall screenFoil plus tinned-copper braid around the whole bundle
RFlexible buildSofter construction for moving or frequently handled runs (DJYVRP, DJYPVRP)
22Steel-tape armourArmoured build for direct burial and mechanical protection
ZR-Flame-retardant prefixSame grid as the base model, flame-retardant sheath

So DJYVP is the overall-screened base, DJYPVP adds a screen to every pair, and DJYVRP is the flexible version of the base. The 22 suffix is the armoured version, and ZR- in front means flame-retardant. Once you can read it, you can read the whole range.

TypeConstruction differenceCarriesChoose it when
DJYVPOverall screen only, twisted pairs.RS-485, 4–20 mA, general instrumentationOne signal type per cable, or pairs that do not disturb each other. The economical default.
DJYPVPAdds an individual screen to every pair, plus the overall screen.Mixed signals in one cable: analogue + digital side by sidePairs must not talk to each other — crosstalk is the failure you are buying against.
DJYVRPFlexible build, overall screen only.Instrument connections that move or are re-terminated oftenThe run flexes or is handled repeatedly; a stiff cable would fatigue at the gland.
DJYPVRPFlexible build, pair screen + overall screen.Mixed signals on a moving or handled runYou need both the pair screening of DJYPVP and the flexibility of DJYVRP.
DJYPVP22 / DJYPVRP22Steel-tape armour over the screened build.Direct burial, cable trays with mechanical risk, outdoor runsThe cable can be crushed, dug into or chewed — the armour, not the screen, is what protects it.

3. The family in numbers

All six members, with selector counts and outer-diameter ranges recomputed from our data. Each model is listed twice in the selector — a standard series and a flame-retardant ZR- series with the same sizes, diameters and weights — so the counts below count selector rows, and the spec ranges show the distinct size grid.

MemberConstructionSelector rowsSpec rangeOuter diameter
DJYVPOverall screen, twisted pairs961–16 pairs × 0.75–1.5 mm²7.1–26.0 mm
DJYPVPPair screen + overall screen902–16 pairs × 0.75–1.5 mm²12.0–30.0 mm
DJYVRPFlexible, overall screen1921–16 pairs × 0.75–1.5 mm²7.2–28.0 mm
DJYPVRPFlexible, pair + overall screen1802–16 pairs × 0.75–1.5 mm²12.0–32.0 mm
DJYPVP22Armoured, pair + overall screen961–16 pairs × 0.75–1.5 mm²9.6–38.0 mm
DJYPVRP22Armoured flexible, pair + overall screen1802–16 pairs × 0.75–1.5 mm²16.0–38.0 mm

The second screen adds diameter more than anything else — compare DJYVP 4 pairs × 1.0 mm² with DJYPVP 4 pairs × 1.0 mm²: the pair-screened build runs noticeably larger at the same pair count, and the armoured builds larger again. That is why the gland and the conduit must be sized from the exact row, never from the base model. Note also that DJYPVP starts at 2 pairs, not 1: a single pair has no neighbour to screen against, so the pair-screened build only makes sense from two pairs up.

4. Worked example: bend radius and six real rows

The minimum bend radius is a multiple of the cable’s outer diameter: 10× for this family. Worked example: DJYPVP 1.0 mm² × 4 pairs (M102030010004) has an outer diameter of 15.0 mm, so it must not be bent tighter than a 150 mm radius. The full method is in our guide to minimum bend radius for drag chain cables.

Six real stock sizes from our cable selector — stock code, model, construction, outer diameter and weight:

Stock codeModelConstructionOuter dia.Weight
M102030007502DJYPVP0.75×2C×2 (2 pairs)12.0 mm156 kg/km
M102030007508DJYPVP0.75×2C×8 (8 pairs)18.0 mm412 kg/km
M102030010004DJYPVP1.0×2C×4 (4 pairs)15.0 mm272 kg/km
M102030010016DJYPVP1.0×2C×16 (16 pairs)27.0 mm868 kg/km
M102030015006DJYPVP1.5×2C×6 (6 pairs)20.0 mm536 kg/km
M102030015016DJYPVP1.5×2C×16 (16 pairs)30.0 mm1,339 kg/km

Find your exact size in the cable selector, or compare the shielding grades in our guide to LiYCY vs LiYY shielded data cables.

5. Which model for which job

Your jobPickWhy
RS-485 bus, one protocol, fixed installationDJYVPOverall screen is enough; pair screening buys nothing when every pair carries the same bus.
Analogue loops + digital signals in one cableDJYPVPPair screens keep the fast digital edges out of the 4–20 mA loops.
Instrument cable to a moving machine part or a panel that is re-terminated oftenDJYVRP / DJYPVRPFlexible build survives handling; pick the pair-screened one if signals are mixed.
Outdoor run, direct burial, tray with mechanical riskDJYPVP22 / DJYPVRP22Steel-tape armour takes the mechanical load; the screens still do the electrical job.
Fire-sensitive installation (public building, tunnel, control room)ZR- version of any of the aboveSame grid, flame-retardant sheath — ask for the ZR- prefix on your model.

6. RS-485 data and the selector grid vs the factory catalogue

For RS-485 duty the published data is: characteristic impedance 120 ± 15 Ω at 1 MHz, test voltage 1.5 kV for 1 minute, insulation resistance ≥ 10 MΩ·km, temperature range −15 °C to +80 °C static and −5 °C to +80 °C dynamic, and minimum bending radius 10× the cable diameter. The sheath is UV resistant, flame retardant, low-temperature and oil resistant. Terminate the shield the right way — our guide to cable glands and 360° shield termination shows the 360° bond and why a pigtail undoes the screening you paid for.

One honest distinction: the factory catalogue lists DJYPVP at 2–50 pairs × 0.5–1.5 mm², while our selector lists the 2–16 pair × 0.75–1.5 mm² grid shown above. The selector covers the sizes most projects actually order; 0.5 mm² conductors and pair counts above 16 are made to order — send the specification and we confirm availability. Anything outside the selector grid is never guessed at here: if it is not in the selector, it is an enquiry, not a stock size.

Frequently asked questions

What is the difference between DJYPVP and DJYVP?
DJYPVP screens every twisted pair individually and then screens the whole bundle again; DJYVP has only the overall screen. DJYPVP is the choice when different signals share one cable and must not interfere with each other. DJYVP is enough when all pairs carry the same signal, such as a single RS-485 bus.
Can DJYPVP be used for RS-485?
Yes — it is built for it. The RS-485 build has a characteristic impedance of 120 ± 15 Ω at 1 MHz, a 300/500 V rating and an overall screen of foil plus tinned copper braid at 80% coverage or more. Use the pair-screened build when the same cable also carries analogue loops.
What pair counts and sizes are in stock?
The selector lists DJYPVP at 2–16 pairs × 0.75, 1.0 and 1.5 mm² — 90 standard rows including the flame-retardant ZR- series. The factory catalogue goes further, to 2–50 pairs × 0.5–1.5 mm²; sizes outside the selector grid are made to order on enquiry.
Do I need the armoured 22 version?
Only where the cable faces mechanical damage: direct burial, outdoor runs, or trays where it can be crushed or cut. Armour protects against force, not noise — if the run is safe indoors, the unarmoured build screens just as well and bends easier at the 10× radius.
What if my size is not in the selector?
Send us the model, pair count, conductor size and outer diameter you need — plus what the cable feeds, so we can confirm the construction. Custom builds start at 300 m, and we usually give a formal quotation within one working day. See also our guide to custom cable assemblies made to drawing.

Send us your model, pair count and diameter

Send the DJYPVP model, pair count and outer diameter — plus what the cable connects, if you want us to confirm the shielding grade. We confirm the construction and usually quote within one working day.

Cable selector WhatsApp Request a quote