Technical guide · Servo and encoder cables · Wiring

A servo motor cable is really two cables in one jacket: a three-phase power feed and a small, separately shielded pair that works the holding brake. Most servo cabling faults — brake chatter, random drive trips, axes that fault only at speed — come from treating it as one plain power cable. Here is the construction, and the wiring rules that go with it.

What is inside

A typical construction from our standard table reads 4 × 1.5 + (2 × 0.5)P — and it decodes as:

  • Four power cores: U, V, W phases plus protective earth, sized to the motor (1.0 mm² for small servos up to 25 mm²).
  • One brake pair: two small cores (commonly 0.5–1.0 mm²) feeding the motor’s 24 V DC holding brake.
  • The (…)P notation: the brake pair carries its own shield, inside the cable’s overall braid shield. Some constructions add a further pair for a temperature sensor.
  • Overall shield: a high-coverage copper braid around everything — the drive’s switching noise stays in, the factory’s noise stays out.

Why the brake pair is shielded separately

The brake pair runs the full length of the cable millimetres from three phase cores carrying fast-switched PWM power. Without its own shield, that noise couples straight into the brake circuit; the classic symptoms are a brake that drags, chatters or releases late, and drive faults that no parameter change fixes. The pair shield is not a luxury feature — on long runs and high switching frequencies it is the difference between a brake circuit and an antenna. It must be terminated, like the overall shield, over the full 360° — a twisted pigtail raises the shield’s impedance at exactly the frequencies that matter.

Fixed or moving? Choose the right servo family

FamilyDutyUse it for
SERVO-CYFixed installationCabinet-to-motor runs that do not move — tray, conduit, machine bed
SERVO-CY-FDDrag chain, mobileMotors on moving axes — built on a high-flex drag chain platform
SERVO-CY-FD-PURDrag chain, harsh dutyThe FD duty plus oil, coolant or outdoor exposure
SERVO-TRVVPMobile, shieldedMoving servo power where a TRVVP-class platform fits the chain

The commonest specification error is a fixed-installation servo cable fitted into a drag chain: the construction is not laid for continuous bending and cores fail early. If the motor moves, the cable must be an FD type. Our selector lists 184 standard servo constructions across these families, fixed and mobile.

Wiring rules that prevent the usual faults

  • Keep the encoder cable separate. Feedback is a different cable (twisted pairs, its own shield) and should never be combined into the power cable or bundled tight against it in the chain.
  • Terminate shields 360° at both ends — EMC gland or clamp at the drive cabinet and at the motor connector. Keep unshielded tails as short as possible.
  • Mind the brake voltage drop. The brake pair is thin by design; on long runs its resistance drops real voltage. If a brake releases weakly at the far end of a long axis, check the voltage at the motor under load before blaming the brake — a larger pair cross-section is the standard fix.
  • Route power and feedback apart in the chain (separate compartments) and cross at right angles where they must meet.
  • In the chain, treat it like any drag chain cable: dynamic bend radius, slack and separators per the installation rules.

Fault patterns

SymptomLikely cabling causeCheck
Brake drags, chatters or releases lateNoise on the brake pair, or voltage drop on a long runPair shield terminated? Voltage at motor under load?
Position faults at speed / in one chain positionEncoder cable shielding or routingSeparate cable? 360° shields? Distance from power run?
Drive EMC / earth faultsOverall shield pigtailed or interrupted at a connectorFull-circumference termination at both ends
Servo cable cores fail in the chainFixed-installation type used in motionIs the fitted type an FD construction?

Frequently asked questions

Can I use a standard shielded cable (TRVVP) as a servo cable?
For power alone it can work electrically, but you lose the integrated, separately shielded brake pair — the brake then needs its own cable, and the pair-shielding problem returns. A purpose-built servo construction is one cable, one chain slot, both circuits correct. See the shielding grades for the background.
Does the brake pair shield connect at both ends?
Yes — like the overall shield, terminate it 360° at the drive end and at the motor end. Floating or single-end shields do not control high-frequency coupling.
Which cross-section do I need?
Power cores follow the motor’s rated current and the drive maker’s table; the brake pair follows run length (voltage drop). Send us the motor rating and the axis length — we will size both from the standard constructions.
Can one cable carry power, brake and encoder together?
Combined “one-cable” servo systems exist for specific drive families with matched connectors, but the general industrial practice — and everything in our standard range — keeps feedback separate. Do not improvise a combined cable from standard parts.

Sizing a servo run?

Motor rating, brake voltage and axis length are all we need. We will pick the construction — fixed or FD, PVC or PUR — from the 184 standard servo types and quote it.

Servo motor cables Open the cable selector